Cryocon Navigation Bar
Products Support Company Home Distributors Home

  Home > Temperature Monitors > Model 12 /14 > Supported Sensors

 

Model 12/14 Cryogenic Temperature Monitor

Supported Sensors


The following is a partial list of temperature sensors that have been tested with the Cryo-con Model 12 and 14 temperature monitors. Additional sensors are usually easy to install. Please review the Model 12/14 User's Guide for details.

Name

Description

Temp Range

FI*

Config.

Mfgr

UpUpCarbon-Ceramic
CCS-ACarbon-Ceramic band A1.5K to 300KUACRTemati
CCS-BCarbon-Ceramic band B2.5K to 300KUACRTemati
CCS-CCarbon-Ceramic band C4.2K to 300KUACRTemati
CCS-DCarbon-Ceramic band D4.2K to 300KUACRTemati
UpUpCarbon-Glass
CGR-1-1000Carbon-Glass2.2 to 325KUACRLakeshore
CGR-1-2000Carbon-Glass2.5 to 325KUACRLakeshore
CGR-1-500Carbon-Glass1.9 to 325KUACRLakeshore
UpUpCernox™
CX-1010Cernox™0.2 to 325KUACRLakeshore
CX-1030-HTCernox™0.3 to 420KUACRLakeshore
CX-1050-HTCernox™1.4 to 420KUACRLakeshore
CX-1070-HTCernox™4.0 to 420KUACRLakeshore
CX-1080-HTCernox™20 to 420KUACRLakeshore
UpUpDiode
CD-12ASilicon Diode1.4 to 500K4DiodeCryo Industries
CTISilicon Diode10 to 300K8DiodeCTI (Obsolete)
DT-414Silicon Diode1.4 to 500K3DiodeLakeshore
DT-421Silicon Diode1.4 to 500K3DiodeLakeshore
DT-470Silicon Diode1.4 to 500K3DiodeLakeshore
DT-471Silicon Diode1.4 to 500K3DiodeLakeshore
DT-670Silicon Diode1.4 to 500K2DiodeLakeshore
GA-300GaAs Diode25 to 500KUDiodeScientific Instruments
S800Silicon Diode1.4 to 400K6DiodeCryo-con
S900Silicon Diode1.4 to 500K7DiodeCryo-con
SI410Silicon Diode1.4 to 500K5DiodeScientific Instruments
SI430Silicon Diode1.4 to 500K7DiodeScientific Instruments
SI440Silicon Diode1.4 to 500K7DiodeScientific Instruments
TG-120GaAs Diode25 to 500KUDiodeLakeshore
UpUpGermanium
GR-200AGermanium0.1K to 100KUACRLakeshore
UpUpPlatinum RTD
CP-100100 Ohm Platinum RTD14 to 873K20PTC100Cryo-con
GP-100100 Ohm Platinum RTD14 to 673K20PTC100Cryo-con
PT100 RTDGeneric 100 Ohm Platinum RTD20 to 800K20PTC100generic
PT-102100 Ohm Platinum RTD14 to 873K20PTC100Lakeshore
PT10K RTDGeneric 10K Ohm Platinum RTD20 to 800K22PTC10Kgeneric
PT-111100 Ohm Platinum RTD14 to 673K20PTC100Lakeshore
PT1K RTDGeneric 1,000 Ohm Platinum RTD20 to 800K21PTC1Kgeneric
XP-100100 Ohm Platinum RTD14 to 425K20PTC100Cryo-con
XP-1K1K Ohm Platinum RTD14 to 425K21PTC1KCryo-con
UpUpRhodium-Iron RTD
PHZ 0002Rhodium-Iron RTD1.4 to 500K23PTC100Oxford
RF-800Rhodium-Iron RTD1.4 to 500K23PTC100Lakeshore
UpUpRuthenium-Oxide
R400Ruthenium-Oxide2.0 to 40K34NTC10uACryo-con
R500Ultra-Low temperature0.4 to 40K33ACRCryo-con
RO-105Ruthenium-Oxide2.0 to 40K32NTC10uAScientific Instruments
RO-600Ultra-Low temperature0.4 to 40K31ACRScientific Instruments
RX-102ARuthenium-Oxide0.4 to 40KUACRLakeshore
RX-102ARuthenium-Oxide2.0 to 40KUACRLakeshore
RX-103ARuthenium-Oxide1.4 to 40KUACRLakeshore
RX-202ARuthenium-Oxide0.4 to 40KUACRLakeshore

*FI = Factory Installed. 0 to 60 indicates that the sensor is supported by a factory installed sensor calibration curve.

U indicates that support in temperature units requires a user supplied curve.


Input configurations are:
 ACR - AC resistance. Constant-voltage excitations of 1.0V, 10mV and 1.0mV.
 Diode - DC Diode. Excitation 10uA DC. Input voltage range: 2.25V
 PTC100 - DC resistance. Excitation 1.0mA DC. Full scale resistance is 625Ω.
 PTC1K - DC resistance. Excitation 100uA DC. Full scale resistance is 6250Ω.
 PTC10K - DC resistance. Excitation 10uA DC. Full scale resistance is 62.5KΩ.


CalGen™ and Cryo-Con™ are registered trademarks of Cryogenic Control Systems, Inc.
All other product and company names are trademarks or trade names of their respective companies.
Tel: (858) 756 3900   Fax: (858) 759 3515   
Specifications subject to change without notice. ©Cryogenic Control Systems, Inc. 1998 - 2010.